Blog Inquiry Contact Jobs
 

RADIAFLEX® 1/2" RCF12-50JFL

Product.Nr.: 850000F

product description

1/2" RADIAFLEX® Radiating Cable

RFS Item Number: RCF12-50JFL

>>> Prices and availability on request!

FEATURES & BENEFITS
  • RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas. Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
  • RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
  • This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a corrugated copper outer conductor which offers a combination of remarkable flexibility, high strength and excellent electrical performance.
  • Broadband radiating cable supporting all wireless application between 75 MHz to 6000 MHz
  • Ideally suited for application that require low bending radii
  • Robust radiating cable operational under all enviromental conditions as e.g. harsh tunnels or mines
  • Euroclass acc. to EN 50575: not available

MECHANICAL SPECIFICATIONS
 
Jacket   JFL
Jacket Color   Standard Black, other colors on request
Jacket Description   Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design   Milled (Two-Row)
Inner Conductor Material   Copper Clad Aluminum Wire
Outer Conductor Material   Corrugated Copper Tube
Diameter Inner Conductor mm (in) 4.8 (0.19)
Diameter Outer Conductor mm (in) 13.8 (0.54)
Diameter over Jacket Nominal mm (in) 16 (0.63)
Minimum Bending Radius, Single Bend mm (in) 125 (4.9)
Cable Weight kg/m (lb/ft) 0.22 (0.15)
Tensile Force N (lb) 1100 (247)
Indication of Slot Alignment   None
Recommended / Maximum Clamp Spacing m (ft) 0.6 (2)
Minimum Distance to Wall mm (in) 50 (1.97)


ELECTRICAL SPECIFICATIONS
 
Max. Operating Frequency MHz 6000
Cable Type   RCF
Impedance Ohm 50 +/- 2
Velocity, percent % 88
Capacitance pF/m (pF/ft) 76 (23.2)
Inductance, uH/m (uH/ft) µH/m (µH/ft) 0.19 (0.058)
DC-resistance inner conductor Ω/km (Ω/1000ft) 1.57 (0.48)
DC-resistance outer conductor Ω/km (Ω/1000ft) 2.23 (0.68)
Stop bands MHz None
Frequency Selection MHz 600, 900, 1800/1900, 2200, 2400, 2500, 2700, 6000

TEMPERATURE SPECIFICATIONS
 
Storage Temperature °C (°F) -70 to 85 (-94 to 185)
Installation Temperature °C (°F) -25 to 60 (-13 to 140)
Operation Temperature °C (°F) -40 to 85 (-40 to 185)

ATTENUATION AND POWER RATING
 
Frequency, MHz Longitudinal Loss, dB/100 m (dB/100 ft) Coupling Loss 50%, dB Coupling Loss 95%, dB
75 2.20 (0.67) 50 62
150 3.15 (0.96) 59 71
450 5.70 (1.74) 67 79
800 7.83 (2.39) 67 79
870 8.25 (2.51) 66 79
900 8.40 (2.56) 66 78
960 8.65 (2.64) 66 78
1800 13.1 (3.99) 68 80
1900 13.6 (4.15) 69 81
2000 14.0 (4.27) 72 84
2200 14.7 (4.48) 70 82
2400 15.3 (4.66) 70 82
2600 15.9 (4.85) 70 82
5000 24.8 (7.56) 75 87
5200 25.7 (7.83) 75 87
5800 27.6 (8.41) 75 87
6000 29.9 (8.81) 75 87