Construction Products Regulation
European Construction Product Regulation for coaxial cables
The European Construction Product Regulation 305/2011 (CPR for short) sets uniform rules for the use of building products within buildings for all EU member states. The implementation of the CPR is regulated by DIN EN 50575: 2017-02. The objective of the CPR / DIN EN 50575 is to increase the fire safety in buildings.
As of July 1st, 2017, the coaxial cables of SSB-Electronic GmbH have a corresponding fire classification and service agreement, as the CPR provides. Correspondingly, the coaxial cables are CE marked.
The CE marking is clearly visible, readable and permanent on the product label.Additional labeling, such as origin, description and fire behavior, can also be found in the labeling. As a manufacture, we provide each tested cable with a service declaration, which contains precise information about the fire behavior, which you can download at any time from our website.
Coaxial Cable | Euroclass according to EN 50575 |
Building Fire Safety Requirements |
Application Area | Classification Criteria | AVCP System (Assessment and Verification of Constancy of Performance) |
Aircell 5 | Eca | low | Cables for standard applications: in buildings with low height or low volume of occupants, in appartments |
Flame propagation EN 60332-1-2 H ≤ 425 mm |
System 3: |
Aircell 7 | |||||
Ecoflex 10 | |||||
Ecoflex 10 PLUS | |||||
Ecoflex 15 | |||||
Ecoflex 15 PLUS | |||||
Aircom Premium | |||||
Ecoflex Multicore | |||||
Ecoflex 10 PLUS Heatex Ecoflex 10 FRNC |
Cca s1 d0 a1 |
high | Cables for areas with increased fire risk: in tower buildings, facilities, administration & office buildings, commercial buildings, restaurants, hotels, underground parking, schools, prisons, leisure facilities, etc. |
Flame propagation EN 60332-1-2 H ≤ 425 mm Heat release, vertical Flame spread EN 50399 FS ≤ 2,0 m THR ≤ 30 MJ max. HRR ≤ 60 kW FIGRA ≤ 300 W/s flame source = 20,5 kW Smoke production EN 50399/EN 61034-2 s1, s1a, s1b, s2, s3 Acidity/Corrosivity EN 60754-2 a1, a2, a3 Flaming droplets EN 50399 d0, d1, d2 |
System 1+: Initial type-testing by third-party notified product certification body Continuous factory inspection by third-party notified product certification body Continuous audit testing of samples by third-party notified product certification body Factory production control (FCB) by manufacturer
|
Ecoflex 15 PLUS Heatex Ecoflex 15 FRNC |
Cca s2 d2 a1 |
||||
Aircell 5 Heatex Aircell 7 Heatex |
Cca s1 d0 a1 |
||||
LCF14-50JFN (RFS) |
B2ca s1a d1 a1 |
very high | Cables for areas with high fire risk: in hospitals, care facilities, day-care centers for children, server rooms, road and railway tunnels, facilities for storing substances with an increased risk of fire, etc. |
||
SCF38-50JFN SCF12-50JFN LCF12-50JFN LCF78-50JFNA (RFS) |
B2ca s1a d0 a1 |
Download Declaration of Performance (DoP):
- Aircell 5
- Aircell 5 Heatex
- Aircell 7
- Aircell 7 Heatex
- Ecoflex 7
- Ecoflex 10 / 10 PLUS
- Ecoflex 10 FRNC
- Ecoflex 15 / 15 PLUS
- Ecoflex 15 FRNC
- Ecoflex 10 PLUS Heatex
- Ecoflex 15 PLUS Heatex
- Aircom Premium
- Aircom Premium FRNC
- Ecoflex Multicore
- H155
Download Declaration of Performance (DoP) of RFS CELLFLEX® cables:
- CELLFLEX® 1/4" SCF14-50JFN
- CELLFLEX® 1/4" LCF14-50JFN
- CELLFLEX® 3/8" SCF38-50JFN
- CELLFLEX® 3/8" LCF38-50JFN
- CELLFLEX® 1/2" SCF12-50JFN
- CELLFLEX® 1/2" LCF12-50JFN
- CELLFLEX® 7/8" LCF78-50JFNA
All CELLFLEX® SCF/LCF cables with jacket option "J" have the Euroclass "F / not classified" because none of the CPR classes are fulfilled.
The products of SSB-Electronic GmbH are therefore safe, tested, classified and thus fully comply with European legislation.
Quality Made in Germany.