product description
1/4" CELLFLEX® Low-Loss Coaxial Cable
RFS Item Number: LCF14-50J
FEATURES & BENEFITS
- Ultra Low Attenuation: the reduced attenuation of CELLFLEX® coaxial cable results in extremly efficient signal transfer in your RF system, especially at high frequencies.
- Complete Shielding: the solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
- Low VSWR: special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise.
- Outstanding Intermodulation Performance: CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
- High Power Rating: due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
- Wide Range of Application: typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects, OEM jumpers, BTS inter-cabinet connections, GPS lines, Microwave IF cabling, intended for outdoor usage.
- Euroclass acc. to EN 50575: Fca
STRUCTURE
| Size | 1/4 | |
| Inner Conductor Diameter | mm (in) | 2.4 (0.094) |
| Inner Conductor Material | Copper-Clad Aluminum Wire | |
| Dielectric Diameter | mm (in) | 6 (0.236) |
| Dielectric Material | Foam Polyethylene | |
| Outer Conductor Diameter | mm (in) | 7.5 (0.295) |
| Outer Conductor Material | Corrugated Copper | |
| Jacket Diameter | mm (in) | 10 (0.394) |
| Jacket Material | Black Polyethylene |
TESTING AND ENVIRONMENTAL
| Phase Stabilized |
Phase stabilized and phase matched cables and accessories are available upon request. |
|
| Compliance |
DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) UL1581 - UV Resistance Jacket IEC 60754-1/-2 |
|
| Installation Temperature | °C(°F) | -40 to 60 (-40 to 140) |
| Storage Temperature | °C (°F) | -70 to 85 (-94 to 185) |
| Operation Temperature | °C(°F) | -50 to 85 (-58 to 185) |
ELECTRICAL SPECIFICATIONS
| Impedance | Ω | 50 +/- 1.5 |
| Maximum Frequency | GHz | 15.8 |
| Velocity | % | 83 |
| Capacitance | pF/m (pF/ft) | 80 (24) |
| Inductance | uH/m (uH/ft) | 0.205 (0.063) |
| Peak Power Rating | kW | 10.9 |
| RF Peak Voltage | Volts | 1050 |
| Jacket Spark | Volt RMS | 5000 |
| Inner Conductor dc Resistance | Ω/1000 m (Ω/1000 ft) | 6.1 (1.86) |
| Outer Conductor dc Resistance | Ω/1000 m (Ω/1000 ft) | 4.4 (1.34) |
| Passive Intermodulation PIM | min. dBc | -160 |
| Return Loss (VSWR) Performance | Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies |
MECHANICAL SPECIFICATIONS
| Cable Weight, Nominal | kg/m (lb/ft) | 0.095 (0.064) |
| Minimum Bending Radius, Single Bend | mm (in) | 40 (1.575) |
| Minimum Bending Radius, Repeated Bends | mm (in) | 85 (3.346) |
| Bending Moment | Nm (lb-ft) | 1.9 (1.4) |
| Tensile Strength | N (lb) | 890 (200) |
| Recommended / Maximum Clamp Spacing | m (ft) | 0.5 / 1 (1.75 / 3.25) |