product description
7/8" RADIAFLEX® Radiating Cable
RFS Item Number: RLK78-50JFLA
>>> Prices and availability on request!FEATURES & BENEFITS
- RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas. Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
- RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
- This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a smooth copper outer conductor which offers a superior electrical performance together with good bending properties.
- Broadband from 30 MHz to 980 MHz
- For applications in tunnels and buildings
- Low coupling loss variations
- Euroclass acc. to EN 50575: Dca s1b d2 a1
MECHANICAL SPECIFICATIONS
| Jacket | JFL | |
| Jacket Description | Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss | |
| Slot Design | Groups of vertical slots at short intervals | |
| Inner Conductor Material | Copper Tube | |
| Outer Conductor Material | Overlapping Copper Strip | |
| Diameter Inner Conductor | mm (in) | 9.3 (0.37) |
| Diameter Outer Conductor | mm (in) | 23.8 (0.94) |
| Diameter over Jacket Nominal | mm (in) | 28.5 (1.12) |
| Minimum Bending Radius, Single Bend | mm (in) | 350 (13.8) |
| Cable Weight | kg/m (lb/ft) | 0.55 (0.37) |
| Tensile Force | N (lb) | 2300 (507) |
| Indication of Slot Alignment | Bulge atop slots | |
| Recommended / Maximum Clamp Spacing | m (ft) | 0.9 (3) |
| Minimum Distance to Wall | mm (in) | 80 (3.15) |
ELECTRICAL SPECIFICATIONS
| Max. Operating Frequency | MHz | 980 | |
| Cable Type | RLK | ||
| Impedance | Ohm | 50 +/- 2 | |
| Velocity, percent | % | 89 | |
| Capacitance | pF/m (pF/ft) | 75 (22.9) | |
| Inductance, uH/m (uH/ft) | µH/m (µH/ft) | 0.188 (0.057) | |
| DC-resistance inner conductor | Ω/km (Ω/1000ft) | 1.74 (0.53) | |
| DC-resistance outer conductor | Ω/km (Ω/1000ft) | 2.52 (0.77) | |
| Stop bands | MHz | 300-375, 675-685 | |
| Frequency Selection | MHz | 600, 900 | |
TEMPERATURE SPECIFICATIONS
| Storage Temperature | °C (°F) | -70 to 85 (-94 to 185) |
| Installation Temperature | °C (°F) | -25 to 60 (-13 to 140) |
| Operation Temperature | °C (°F) | -40 to 85 (-40 to 185) |
ATTENUATION AND POWER RATING
| Frequency, MHz | Longitudinal Loss, dB/100 m (dB/100 ft) | Coupling Loss 50%, dB | Coupling Loss 95%, dB |
| 75 | 1.08 (0.33) | 46 (50) | 58 (60) |
| 150 | 1.56 (0.48) | 54 (58) | 66 (69) |
| 380 | 2.69 (0.81) | 53 (55) | 57 (59) |
| 400 | 2.70 (0.82) | 53 (55) | 57 (59) |
| 450 | 2.90 (0.88) | 52 (55) | 56 (59) |
| 470 | 2.97 (0.91) | 52 (55) | 56 (59) |
| 500 | 3.10 (0.94) | 52 (55) | 56 (59) |
| 800 | 4.35 (1.33) | 55 (58) | 59 (62) |
| 870 | 4.90 (1.49) | 56 (59) | 61 (64) |
| 900 | 5.05 (1.54) | 57 (60) | 62 (65) |
| 960 | 5.19 (1.58) | 57 (60) | 62 (65) |