product description
7/8" RADIAFLEX® Radiating Cable
RFS Item Number: RAY78-50JFLA
>>> Prices and availability on request!FEATURES & BENEFITS
- RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas. Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
- RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
- This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a smooth copper outer conductor which offers a superior electrical performance together with good bending properties.
- Broadband from 30 MHz to 1000 MHz
- Optimized for high frequencies and digital transmission
- For tunnel applications
- Low coupling loss variations
- Euroclass acc. to EN 50575: Dca s1b d2 a1
MECHANICAL SPECIFICATIONS
Jacket | JFL | |
Jacket Description | Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss | |
Slot Design | Groups of slope slots at short intervals | |
Inner Conductor Material | Copper Tube | |
Outer Conductor Material | Overlapping Copper Strip | |
Diameter Inner Conductor | mm (in) | 9.3 (0.37) |
Diameter Outer Conductor | mm (in) | 23.8 (0.94) |
Diameter over Jacket Nominal | mm (in) | 28.5 (1.12) |
Minimum Bending Radius, Single Bend | mm (in) | 350 (13.8) |
Cable Weight | kg/m (lb/ft) | 0.55 (0.37) |
Tensile Force | N (lb) | 2300 (507) |
Indication of Slot Alignment | Bulge atop slots | |
Recommended / Maximum Clamp Spacing | m (ft) | 0.9 (3) |
Minimum Distance to Wall | mm (in) | 80 (3.15) |
ELECTRICAL SPECIFICATIONS
Max. Operating Frequency | MHz | 1000 | |
Cable Type | RAY | ||
Impedance | Ohm | 50 +/- 2 | |
Velocity, percent | % | 89 | |
Capacitance | pF/m (pF/ft) | 75 (22.9) | |
Inductance, uH/m (uH/ft) | µH/m (µH/ft) | 0.188 (0.057) | |
DC-resistance inner conductor | Ω/km (Ω/1000ft) | 1.74 (0.53) | |
DC-resistance outer conductor | Ω/km (Ω/1000ft) | 2.52 (0.77) | |
Stop bands | MHz | 240-300, 500-590, 750-860 | |
Frequency Selection | MHz | 600, 900 |
TEMPERATURE SPECIFICATIONS
Storage Temperature | °C (°F) | -70 to 85 (-94 to 185) |
Installation Temperature | °C (°F) | -25 to 60 (-13 to 140) |
Operation Temperature | °C (°F) | -40 to 85 (-40 to 185) |
ATTENUATION AND POWER RATING
Frequency, MHz | Longitudinal Loss, dB/100 m (dB/100 ft) | Coupling Loss 50%, dB | Coupling Loss 95%, dB |
75 | 1,04 (0,32) | 53 (57) | 62 (66) |
150 | 1,48 (0,45) | 58 (62) | 69 (73) |
450 | 2,67 (0,81) | 60 (62) | 67 (69) |
870 | 5,41 (1,65) | 54 (56) | 63 (65) |
900 | 5,70 (1,74) | 54 (56) | 61 (63) |
960 | 6,46 (1,97) | 54 (56) | 60 (62) |