Downloads Inquiry Contact
 

RADIAFLEX® 1/2" RLKAX12-50JFNA

Product.Nr.: 823000F

product description

1/2" RADIAFLEX® Radiating Cable

RFS Item Number: RLKAX12-50JFNA

>>> Prices and availability on request!

FEATURES & BENEFITS
  • RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas. Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
  • RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
  • This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a smooth copper outer conductor which offers a superior electrical performance together with good bending properties.
  • Ultra-wideband from 30 MHz to 7200 MHz
  • Support of 4G and 5G wireless bands and WLAN standards
  • Suitable for a wide range of applications in tunnels and buildings
  • Low coupling loss variations for balanced system design througout the overall supported spectrum
  • Euroclass acc. to EN 50575: Cca s1a d1 a1

MECHANICAL SPECIFICATIONS
 
Jacket   JFN
Jacket Description   Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin
Slot Design   Groups of vertical slots at short intervals
Inner Conductor Material   Copper Clad Aluminum Wire
Outer Conductor Material   Overlapping Copper Foil
Diameter Inner Conductor mm (in) 4.37 (0.17)
Diameter Outer Conductor mm (in) 11.4 (0.45)
Diameter over Jacket Nominal mm (in) 14.7 (0.58)
Minimum Bending Radius, Single Bend mm (in) 200 (7.9)
Cable Weight kg/m (lb/ft) 0.23 (0.16)
Tensile Force N (lb) 1300 (292)
Indication of Slot Alignment   Bulge atop slots
Recommended / Maximum Clamp Spacing m (ft) 0.5 (1.6)
Minimum Distance to Wall mm (in) 80 (3.15)


ELECTRICAL SPECIFICATIONS
 
Max. Operating Frequency MHz 7200
Cable Type   RLKAX
Impedance Ohm 50 +/- 2
Velocity, percent % 88
Capacitance pF/m (pF/ft) 75 (22.9)
Inductance, uH/m (uH/ft) µH/m (µH/ft) 0.188 (0.057)
DC-resistance inner conductor Ω/km (Ω/1000ft) 1.97 (0.6)
DC-resistance outer conductor Ω/km (Ω/1000ft) 4.84 (1.48)
Stop bands MHz 1900-2190
Frequency Selection MHz 2400, 2600, 3500, 3800, 4200, 4900, 5800, 7000

TEMPERATURE SPECIFICATIONS
 
Storage Temperature °C (°F) -70 to 85 (-94 to 185)
Installation Temperature °C (°F) -25 to 60 (-13 to 140)
Operation Temperature °C (°F) -40 to 85 (-40 to 185)

ATTENUATION AND POWER RATING
 
Frequency, MHz Longitudinal Loss, dB/100 m (dB/100 ft) Coupling Loss 50%, dB Coupling Loss 95%, dB
75 2.09 (0.64) 62 (65) 72 (75)
150 2.96 (0.90) 72 (75) 81 (85)
450 5.25 (1.60) 75 (78) 86 (89)
700 6.60 (2.01) 74 (78) 85 (88)
900 7.57 (2.31) 74 (77) 84 (87)
1500 10.0 (3.05) 79 (82) 90 (92)
1700 10.8 (3.29) 73 (76) 84 (86)
1800 11.1 (3.38) 75 (77) 86 (88)
2200 12.8 (3.90) 64 (68) 73 (77)
2400 13.4 (4.08) 68 (70) 75 (77)
2600 14.1 (4.30) 66 (69) 71 (75)
2700 14.5 (4.42) 68 (70) 74 (77)
3200 15.8 (4.82) 68 (72) 74 (79)
3400 16.4 (5.00) 67 (71) 72 (76)
3600 17.0 (5.18) 68 (72) 72 (77)
3800 17.7 (5.39) 66 (70) 70 (75)
4000 18.5 (5.64) 69 (73) 74 (78)
4200 19.1 (5.82) 64 (68) 68 (73)
4800 21.1 (6.43) 66 (70) 71 (76)
5000 21.8 (6.64) 65 (69) 70 (75)
5200 22.5 (6.86) 65 (69) 70 (75)
5400 23.3 (7.10) 65 (69) 69 (73)
5600 24.2 (7.38) 66 (69) 70 (75)
5800 25.1 (7.65) 66 (70) 72 (76)
6000 26.0 (7.92) 64 (68) 69 (73)
6200 26.8 (8.17) 65 (68) 69 (74)
6400 28.0 (8.53) 64 (68) 70 (74)
6600 29.1 (8.87) 63 (67) 68 (72)
6800 30.5 (9.30) 63 (67) 69 (73)
7000 32.1 (9.78) 63 (67) 69 (73)
7200 33.9 (10.3) 63 (66) 68 (72)