product description
1/2" RADIAFLEX® Radiating Cable
RFS Item Number: RCF12-50JFN
>>> Prices and availability on request!FEATURES & BENEFITS
- RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas. Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
- RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
- This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a corrugated copper outer conductor which offers a combination of remarkable flexibility, high strength and excellent electrical performance.
- Broadband radiating cable supporting all wireless application between 75 MHz to 6000 MHz
- Ideally suited for application that require low bending radii
- Robust radiating cable operational under all enviromental conditions as e.g. harsh tunnels or mines
- Euroclass acc. to EN 50575: Cca s1a d1 a1
MECHANICAL SPECIFICATIONS
Jacket | JFN | |
Jacket Color | Standard Black, other colors on request | |
Jacket Description | Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin | |
Slot Design | Milled (Two-Row) | |
Inner Conductor Material | Copper Clad Aluminum Wire | |
Outer Conductor Material | Corrugated Copper Tube | |
Diameter Inner Conductor | mm (in) | 4.8 (0.19) |
Diameter Outer Conductor | mm (in) | 13.8 (0.54) |
Diameter over Jacket Nominal | mm (in) | 16 (0.63) |
Minimum Bending Radius, Single Bend | mm (in) | 125 (4.9) |
Cable Weight | kg/m (lb/ft) | 0.22 (0.15) |
Tensile Force | N (lb) | 1100 (247) |
Indication of Slot Alignment | None | |
Recommended / Maximum Clamp Spacing | m (ft) | 0.6 (2) |
Minimum Distance to Wall | mm (in) | 50 (1.97) |
ELECTRICAL SPECIFICATIONS
Max. Operating Frequency | MHz | 6000 | |
Cable Type | RCF | ||
Impedance | Ohm | 50 +/- 2 | |
Velocity, percent | % | 88 | |
Capacitance | pF/m (pF/ft) | 76 (23.2) | |
Inductance, uH/m (uH/ft) | µH/m (µH/ft) | 0.19 (0.058) | |
DC-resistance inner conductor | Ω/km (Ω/1000ft) | 1.57 (0.48) | |
DC-resistance outer conductor | Ω/km (Ω/1000ft) | 3.48 (1.06) | |
Stop bands | MHz | None | |
Frequency Selection | MHz | 600, 900, 1800/1900, 2200, 2400, 2500, 2700, 6000 |
TEMPERATURE SPECIFICATIONS
Storage Temperature | °C (°F) | -70 to 85 (-94 to 185) |
Installation Temperature | °C (°F) | -25 to 60 (-13 to 140) |
Operation Temperature | °C (°F) | -40 to 85 (-40 to 185) |
ATTENUATION AND POWER RATING
Frequency, MHz | Longitudinal Loss, dB/100 m (dB/100 ft) | Coupling Loss 50%, dB | Coupling Loss 95%, dB |
75 | 2.20 (0.67) | 50 | 62 |
150 | 3.15 (0.96) | 59 | 71 |
450 | 5.70 (1.74) | 67 | 79 |
800 | 7.83 (2.39) | 67 | 79 |
870 | 8.25 (2.51) | 66 | 79 |
900 | 8.40 (2.56) | 66 | 78 |
960 | 8.65 (2.64) | 66 | 78 |
1800 | 13.1 (3.99) | 68 | 80 |
1900 | 13.6 (4.15) | 69 | 81 |
2000 | 14.0 (4.27) | 72 | 84 |
2200 | 14.7 (4.48) | 70 | 82 |
2400 | 15.3 (4.66) | 70 | 82 |
2600 | 15.9 (4.85) | 70 | 82 |
5000 | 24.8 (7.56) | 75 | 87 |
5200 | 25.7 (7.83) | 75 | 87 |
5800 | 27.6 (8.41) | 75 | 87 |
6000 | 29.9 (8.81) | 75 | 87 |